A
RF73
User Guide
Ref. 09-07-V1-smn p 6
Radio communication
Radio communication
Radio communication is performed when the modem is set in transceiver
mode (this is the default at power-up).
The radio data rate is fixed to 9600bps.
The output power may be programmed to 0.5W, 2W or 4W to either optimize
covered range or power consumption.
Radio channels
The S250 registers determined the center frequency of the bandwidth of the
modem. The modem is calibrated during factory process on this central
frequency which can not be changed by using command mode. For this
reason, S250 is a read only register.
By default, the modem is delivered with a predefined frequency table
recorded in S200 register. The central frequency corresponding to the S250
register can be found in this table at position 8. First frequency of the table is
referred has position 0.
The frequency table can freely (with respect of 12.5kHz of spacing) be
changed using command mode of the product in a range of +/-3.5MHz
around the central frequency displayed in S250. Note that the frequency
must be written with 4 digits after the point even if they are zeros. Each new
frequency must be separated by entering a <CR> char.
The channel selected from the frequency table for radio transmission and
reception is set in S201 register. S201=0 corresponds to the first channel of
the frequency table, S201=15 is the last one.